Mã lỗi máy photocopy A0


 BẢNG MÃ LỖI RICOH A0: 240W, 2400W, 3600W, 4800W, 5100W

More Sharing ServicesShare|Share on facebookShare on twitterShare on emailShare on print

AFICIO RICOH 240W, SC CODE-NGUYÊN NHÂN & CÁCH KHẮC PHỤC.
---------------********--------------

Code

NGYÊN NHÂN

KHẮC PHỤC

300

Charge Corona Output Error
The charge-corona feedback voltage was less than 1 V for more than 200 ms.

Replace the charge corona unit. • Replace the high voltage cable. • Clean or replace the corona wire. • Check the CGB power pack fuse, connection. • Replace the CGB power pack.

305

Charge Corona Wire Cleaner Error
The charge wire cleaner did not a) come from the home position within 5 s, or b) did not go back to the home position in 3.7 s or less. This is because of wire cleaner overload.

• Switch the main power switch off/on. • Check the wire cleaner unit for a blockage or broken parts.

330

Writing ASIC Signal Error
At power on, the stamp function could not start.

• Check the setting of SP5137. If the stamp option is installed, this SP must be enabled. If the stamp option is not installed, this SP must be disabled. • Check the stamp board connections. • Replace the defective stamp board.

360

Hard Disk Connection Error
The machine could not detect the HDD connection.

• Check the connections between the HDD and hard disk controller. • Check the HDD power connector. • Replace the HDD. • Replace the MCU.

361

Hard Disk Read Errors

• Do SP4960-1 (HDD Media Check). • Do SP4906 003 to format the HDD. • If formatting the HDD fails, replace the HDD.

362

IMAC (Image Memory Access Controller) error
During data transfer in memory at the IPU, an error occurred during data compression with ASIC (IMAC). The ASIC controls data compression.

• Update the firmware. • If the firmware update does not stop the problem, replace the IPU board. • Update all software modules if this problem continues.

380

MSU Output Error
Just after the machine was switched on, it could not detect that the MSU (Memory Super-charger Unit) was set.

• Replace the IPU.

392

Development Bias Error
The development bias feedback voltage was less than 0.5 V for longer than 200 ms while the PWM duty value was more than 5% (indicating a development bias leak).

• Check the MCU connectors. • Check the harness on the MCU for damage. • Replace the high voltage cable. • Replace the CGB power pack.

400

ID Sensor Auto Adjustment Error
Vsg did not get to 4±0.2 V when the ID sensor was adjusted automatically in the SP mode.

• Clean the ID sensor. • Check the ID sensor harness and connector. • Replace the ID sensor. • Replace the MCU. • Replace the development unit. • Replace the CGB power pack.

401

ID Sensor Vsg Error
The Vsg level was detected lower than 2.5 V two times.

• Clean the ID sensor. • Check the ID sensor harness and connector. • Replace the ID sensor. • Replace the MCU. • Replace the development unit. • Replace the CGB power pack.

402

ID Sensor Vsp Error
The Vsp level was detected at 0 V or more than 2.5 V for 2 consecutive copies.

• Under the left upper cover, make sure that the hex screw of the main drive gear of the drum is tight. • Clean the ID sensor. • Check the ID sensor harness and connector. • Replace the ID sensor. • Replace the MCU. • Replace the development unit. • Replace the CGB power pack.

440

Transfer Output Error
A high voltage feedback voltage of less than 1.0 V was detected for 200 ms.

• Check and replace the high voltage cable if necessary. • Replace the CGB power pack.

460-1

DC Separation Corona Output Error
A dc separation feedback voltage of less than 1.0 V was detected after more than 200 ms while the PWM duty value was more than 15%.

• Check and replace the high voltage cable if necessary. • Replace the CGB power pack.

508

Cutter Error
The left and right cutter HP sensors stayed on or off more than 2 seconds.

• Check the connections of the HP sensors on the left and right side. • Replace the HP sensors.

520

Main Motor Error
The lock signal goes LOW after the motor starts and gets to the set speed. If the main motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.

• Check that the motor drive path is not overloaded. • Replace the motor harness. • Replace the motor.

Code

Description

Causes

521

Drum Motor Error
The lock signal goes LOW after the motor starts and gets to the set speed. If the drum motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.

• Check that the motor drive path is not overloaded. • Replace the motor.

522

Fusing Unit Drive Motor
Error The lock signal goes LOW after the motor starts and gets to the set speed. If the fusing motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.

• Check that the motor drive path is not overloaded. • Replace the motor.

530

Fusing Unit Ventilation Fan Error
The lock signal goes LOW after the motor starts and gets to the set speed. If the fan motor lock signal stayed HIGH for 5 seconds during motor operation, the motor stopped because of overloading.

• Check that the motor is not overloaded. • Replace the motor.

541-1

Fusing Thermistor Error 1
• The measured temperature of the hot roller stayed below 7C (44.6F) for 60 seconds after the machine was switched on. -or- • During machine operation the hot roller temperature fell to and stayed at 7C (44.6F) for 40 seconds.

• Make sure that the thermistor is set correctly. • Make sure that the thermistor cable is connected. • Replace the thermistor.

541-2

Fusing Thermistor Error 2
The analog voltage input from the hot roller temperature was less than 2 V for three measurements. The thermistor has short-circuited.

• Replace the thermistor.

542

Fusing Temperature Warm-up Error
The hot roller did not get to the ready temperature within 4 minutes 30 sec.: • After the machine was switched on. • After the upper unit or roll feeder drawer was closed. • During warm-up.

• Check the fusing lamp connections. • Replace the fusing lamp. • Replace the MCU. • Check the hot roller thermistor. Make sure that it is straight and does not touch the hot roller.

543

Fusing Lamp Overheated: Error 1 (Software)
A fusing temperature more than 230 °C (446°F) was detected 3 times (measured at 180 ms intervals). Note: A shorted triac or other problem could cause the fusing lamp to stay on.

• Replace the MCU.

544

Fusing Lamp Overheated: Error 2 (Hardware)
A short circuit in the triac on the MCU caused the fusing temperature control to stop or operate incorrectly. A special circuit on the MCU monitors the temperature of the board. The temperature around the board was more than 235C. 544-1 Latch Signal On (50 ms) 544-2 Signal On (1 s)

• Replace the MCU.

545

Fusing Lamp Overheated: Error 3
After it got to the ready temperature, the fusing lamp stayed on at full power for 50 seconds while the hot roller did not turn.

Correct the position of the thermistor on the hot roller. Replace the fusing lamp harness. Replace the MCU.

546-1

Fusing Temperature Error 1
Fusing temperature goes up and down quickly, more than 20°C (68°C) at 1 sec. intervals.

• Check the thermistor connection. • Check the fusing lamp connections. • Replace the MCU.

546-2

Fusing Temperature Error 2
Temperature goes up and down during a long interval, by 20°C (68°C) more than 3 times during a 60 sec. interval.

• Check the thermistor connection. • Check the fusing lamp connections. • Replace the MCU.

547

Zero-Cross Signal Errors
The zero-cross signal from the ac power supply makes a trigger pulse to control the supply of power. It automatically detects 50/60 Hz.

• Check that the frequency of the power supply to the machine is correct. • Replace the PSU. • Replace the MCU

548

Fusing Lamps Disconnected
The fusing temperature did not get to 100°C within 2 min. after the machine was switched on.

• Check the fusing lamp harness connections. • Replace the fusing lamps. • Replace the AC drive board.

549-1

Pressure Roller Thermistor Error 1
Fusing temperature control detected that the analog voltage output by the pressure roller thermistor was more than 5V. The pressure roller thermistor is disconnected.

• Check the thermistor connection. • Replace the thermistor. • Replace the MCU.

549-2

Pressure Roller Thermistor Error 2
(2 times at 1.5 sec. intervals) that the analog voltage output by the pressure roller thermistor was less than 0.2 V. The pressure roller thermistor has short-circuited.

• Check the thermistor connection. • Replace the thermistor. • Replace the MCU.

Code

Description

Causes

601

Communication Error Between IPU and CIS
A break signal was detected after the communication connection. A communication error was sent back 3 times.

• Update the software. • Replace the MCU.

605

Communication Error Between Controller and ECU
One of these problems occurred: • Serial communication error • Serial data overflowed in the receive data buffer.

• Replace the MCU.

630

CSS Communication Error (Japan Only)
The machine sent a report on its condition, but CSS detected an error. There is a problem on the telephone line between the machine location and the CSS center.

• No action necessary.

632

MK1 Communication Error 1: No Answer to ACK
The optional counter device did not send an ACK signal 100 ms after one frame was sent, even after the same data was sent 3 times.

• Check the serial line harnesses and connectors at the counter device, the relay board, and the controller. • Replace the counter device. • Replace the MCU.

633

MK1 Communication Error 2: BREAK Received
A LOW break signal was received while the optional counter device was connected to the communication circuit.

• Check the serial line harnesses and connectors at the counter device, the relay board, and the controller. • Replace the counter device. • Replace the MCU.

900

Electrical Total Counter
The electrical counter is not connected.

• Replace NVRAM chips.

901

Mechanical Total Counter
The mechanical counter is not connected.

• Check the mechanical counter connection. • Replace the mechanical counter.

980

HDD Access Error

• Update the MCU firmware

981

HDD Response Errors

• Check the HDD Connectors. • Check the HDD and make sure that it is not loose. • Update the MCU firmware. • Replace the HDD.

991

Software Error 1: SCU
There was an unusual operation by the software because of: • An incorrect argument in the program. • An incorrect internal parameter. • Work memory not sufficient. • An error occurred that could not be detected by other SC codes.

• Set the main power switch to .off. then to .on.. • Go into the SP mode. • Input .0. for SP7405 to display the data for SC991, which includes the software file name, line number, and variable.

992

Software Error 2: ECU
There was an unusual operation by the software because of: • An incorrect argument in the program. • An incorrect internal parameter. • Work memory not sufficient. • An error occurred that could not be detected by other SC codes.

• Set the main power switch to .off. then to .on.. • Go into the SP mode. • Input .0. for SP7405 to display the data for SC992, which includes the software file name, line number, and variable.

 

                                                   MAYPHOTOCOPYGIARE.VN  - CHÚC CÁC BẠN THÀNH CÔNGOICOPYMÀYDSFDGFD
MỌI THẮC MẮC VỀ KỸ THUẬT XIN LIÊN HỆ Mr. HUY – 0972.81 83 86

TIN NỔI BẬT

HỖ TRỢ TRỰC TUYẾN

  • Kinh doanh 1 (6 line) : 024.3999 5886

  • Kinh doanh 2 (6 line) : 0972.81.83.86

  • Kinh doanh 3 : 0945.00.3886

  • Hỗ trợ kỹ thuật : 0972. 81.83.86

  • BÁN HÀNG TRỰC TUYẾN
  • icon-mobile

    0243.999.5886 - 0945.00 3886 - 0972.81 83 86