| Code | NGUYÊN NHÂN | KHẮC PHỤC | 
        
            | SC101 | Exposure lamp errorThe white level peak did not reach the prescribed threshold when the white   plate was scanned.
 | • Dirty optics • Dirty white plate •   Exposure lamp defective • Exposure lamp does not turn on • Lamp stabilizer   defective • High voltage line leak • SIB defective • SBU defective | 
        
            | SC120 | Scanner home position error 1The scanner home position sensor did not detect the home position (did not go   OFF) after the scanner moved forward 20 mm..
 | • Scanner motor defective • Scanner HP sensor   defective • Harness between scanner motor and SIOB disconnected or broken. •   SIOB defective | 
        
            | SC121 | Scanner home position error 2The scanner home position sensor did not go ON after the scanner moved   forward 6 mm and the feeler entered the HP sensor.
 | • Scanner motor harness loose, broken,   defective • Scanner motor defective • Scanner HP sensor disconnected,   defective • SIOB defective | 
        
            | SC141 | Black level detection errorDuring AGC the value for black level was not within ±3 of the prescribed   value.
 | • SBU defective • Harness defective • Check   harnesses between SBU and IPU • IPU defective • VBCU defective | 
        
            | SC142 | White level detection errorDuring AGC the value for white level was not within -7 of the prescribed   value.
 | • Exposure lamp defective • Harness disconnected,   damaged • Dirty exposure glass, optics • Scanner motor, drive assembly   defective • SBU board defective | 
        
            | SC143 | SBU Auto Adjust ErrorAt power on the automatic white level adjustment failed.
 | • Clean the white plate • Clean the optics   and lenses • Check the connectors between the SBU and IPU. • Replace the SBU   • Replace the IPU • Replace the VBCU • Replace the exposure lamp | 
        
            | SC144 | SBU communication errorWhen the machine is switched on, or when the machine returns to full   operation from the energy save mode, the machine can not access the SBU   register, or the SBU register values are abnormal. Note: The ASIC IDs read   during automatic adjustment of the SBU can be displayed with SP4600.
 | • SBU harness loose, disconnected, defective   • SBU board defective • VBCU defective | 
        
            | SC161 | IPU errorCommunication error between IPU, SBU, and VBCU.
 | • Check harness connections between SBU and   IPU/VBCU • IPU defective • VBCU defective | 
        
            | SC165 | Illegal Copy Prevention ErrorAn abnormality was detected with the ICIB board at power on.
 | • ICIB connected incorrectly • ICIB   defective | 
        
            | SC180 | Scanner fan lock The fan motor next to the   SIOB did not switch on within 10 sec. after the CPU issued the ON signal. | • Fan defective • Foreign object interfering   with operation of fan • Motor harness loose, disconnected, or broken • SIOB   defective | 
        
            | SC181 | Scanner Fan Error: Lamp StabilizerThe exposure lamp regulator fan is not rotating.
 | • Check the fan connections • Fan defective   • Check SBU connection • Check SIOB connection • SBU defective • SIOB   defective | 
        
            | SC182 | Scanner Fan Error: Right SideThe fan located on the right side of the exposure unit is not rotating.
 | • Check the fan connections • Fan defective   • Check SBU connection • Check SIOB connection • SBU defective • SIOB   defective | 
        
            | SC195 | Machine serial number errorThe number registered for the machine serial number does not match.
 | • Confirm the correct serial number of the   machine in the specifications • Important: When SC195 occurs, the serial   number must be input. Please contact your technical supervisor. | 
        
            | SC202 | Polygon motor error: ON timeoutThe polygon mirror motor does not reach the targeted operating speed within   the prescribed time
 | • Harness to polygon motor drive board   disconnected, defective • Polygon motor defective • Polygon motor drive board   defective • Polygon motor defective. | 
        
            | SC203 | Polygon motor error: OFF timeoutThe polygon mirror motor does leave the READY status within 3 seconds after   the polygon motor switches off.
 | • Harness to polygon motor driver board   disconnected, defective • Polygon motor defective • Polygon motor driver   board defective • Polygon motor defective. | 
        
            | Code | Description | Causes | 
        
            | SC204 | Polygon motor error: XSCRDY signal errorThe polygon motor stopped operating while the LD unit was firing.
 | • Harness to polygon motor driver board   disconnected, defective • Polygon motor defective • Polygon motor driver   board defective | 
        
            | SC210 | Laser beam detection error: K (Black)The laser synchronization sensor failed to detect the beginning and end of   the laser beam flash for the designated color onto the polygon mirror while   the mirror is rotating at the prescribed number of revolutions.
 | • Laser synchronization detector sensor   connection loose, not connected • Laser synchronization detector sensor   defective • LD unit defective • IPU defective • VBCU defective | 
        
            | SC211 | Laser beam detection error: Y (Yellow)The laser synchronization sensor failed to detect the beginning and end of   the laser beam flash for the designated color onto the polygon mirror while   the mirror is rotating at the prescribed number of revolutions.
 | • Laser synchronization detector sensor   connection loose, not connected • Laser synchronization detector sensor   defective • LD unit defective • IPU defective • VBCU defective | 
        
            | SC212 | Laser beam detection error: M (Magenta)The laser synchronization sensor failed to detect the beginning and end of   the laser beam flash for the designated color onto the polygon mirror while   the mirror is rotating at the prescribed number of revolutions.
 | • Laser synchronization detector sensor   connection loose, not connected • Laser synchronization detector sensor   defective • LD unit defective • IPU defective • VBCU defective | 
        
            | SC213 | Laser beam detection error: C (Cyan)The laser synchronization sensor failed to detect the beginning and end of   the laser beam flash for the designated color onto the polygon mirror while   the mirror is rotating at the prescribed number of revolutions.
 | • Laser synchronization detector sensor   connection loose, not connected • Laser synchronization detector sensor defective   • LD unit defective • IPU defective • VBCU defective | 
        
            | SC220 | Laser Synchronization Detector Error: K   Leading Edge: LD0While the polygon motor is rotating normally, no synchronizing detection   signal is output for LD0 black, or leading edge, even after the laser diode   has been firing for 2 sec.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC221 | Laser Synchronization Detector Error: K   Leading Edge (Not LD0)While the polygon motor is rotating normally, no synchronizing detection   signal is output for black, leading edge for any LD other than LD0.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC222 | Laser Synchronization Detector Error: Y   Leading Edge: LD0While the polygon motor is rotating normally, no synchronizing detection   signal is output for LD0 yellow, leading edge.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC223 | Laser Synchronization Detector Error: Y   Leading Edge (Not LD0)While the polygon motor is rotating normally, no synchronizing detection   signal is output for yellow, leading edge for any LD other than LD0.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC224 | Laser Synchronization Detector Error: M   Leading Edge: LD0While the polygon motor is rotating normally, no synchronizing detection   signal is output for LD0 magenta, leading edge.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC225 | Laser Synchronization Detector Error: M   Leading Edge (Not LD0)While the polygon motor is rotating normally, no synchronizing detection   signal is output for magenta, leading edge for any LD other than LD0.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC226 | Laser Synchronization Detector Error: C   Leading Edge: LD0While the polygon motor is rotating normally, no synchronizing detection   signal is output for LD0 cyan, leading edge.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC227 | Laser Synchronization Detector Error: C   Leading Edge (Not LD0)While the polygon motor is rotating normally, no synchronizing detection   signal is output for cyan, leading edgefor any LD other than LD0.
 | • Harness between the laser synchronizing   detector and I/F unit is disconnected, defective • Check all connections   between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective | 
        
            | SC230 | FGATE error: Feedback remains HIGH for K   writeAfter the start of timing to create the black image, the PFGATE register of   the GAVD did not assert
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC231 | FGATE error: Feedback remains LOW for K   writeAfter the start of timing to create the black image, the PFGATE register of   the GAVD did not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | Code | Description | Causes | 
        
            | SC232 | FGATE error: Feedback remains HIGH for Y   writeAfter the start of timing to create the yellow image, the PFGATE register of   the GAVD did not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC233 | FGATE error: Feedback remains LOW for Y   writeAfter the start of timing to create the yellow image, the PFGATE register of   the GAVD did not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC234 | FGATE error 1: Feedback remains HIGH for M   writeAfter the start of timing to create the magenta image, the PFGATE register of   the GAVD did not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC235 | FGATE error: Feedback remains LOW for M writeAfter the start of timing to create the magenta image, the PFGATE register of   the GAVD does not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC236 | FGATE error 1: Feedback remains HIGH for C   writeAfter the start of timing to create the cyan image, the PFGATE register of   the GAVD did not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC237 | FGATE error: Feedback remains LOW for C   writeAfter the start of timing to create the cyan image, the PFGATE register of   the GAVD does not assert.
 | • Harness between the VBCU and LDB unit   disconnected, loose, or defective. • LD unit defective • IPU defective •   Controller board disconnected, defective • HDD defective | 
        
            | SC240 | LD error: KAn error occurred at the LD error terminal of the K, Y, M, or C LD driver after   initialization of the LD because the power to the LD was higher or lower than   the prescribed limit.
 | • LD defective due to wear, damage, short   circuit • LDB harness disconnected, loose or defective | 
        
            | SC241 | LD error: YAn error occurred at the LD error terminal of the K, Y, M, or C LD driver   after initialization of the LD because the power to the LD was higher or   lower than the prescribed limit.
 | • LD defective due to wear, damage, short   circuit • LDB harness disconnected, loose or defective | 
        
            | SC242 | LD error: MAn error occurred at the LD error terminal of the K, Y, M, or C LD driver   after initialization of the LD because the power to the LD was higher or   lower than the prescribed limit.
 | • LD defective due to wear, damage, short   circuit • LDB harness disconnected, loose or defective | 
        
            | SC243 | LD error: CAn error occurred at the LD error terminal of the K, Y, M, or C LD driver   after initialization of the LD because the power to the LD was higher or   lower than the prescribed limit.
 | • LD defective due to wear, damage, short   circuit • LDB harness disconnected, loose or defective | 
        
            | SC268 | Optical unit sensor errorAt power on, one of the two temperature sensors in the optics unit detected a   temperature lower than -10°C. -or- It detected a temperature higher than   80°C.
 | • Thermistor disconnected (causes extremely   low temperature reading) • Thermistor damaged and short circuited (causes   extremely high temperature reading) • VBCU defective | 
        
            | SC270 | Skew Control Upper Lower Limit: YThe pulse total for Yellow skew control is not within the prescribed range.
 | • ITB not installed correctly. • ITB   defective • Optical unit installed incorrectly • Optical unit defective | 
        
            | SC271 | Skew Control Upper Lower Limit: MThe pulse total for Magenta skew control is not within the prescribed range.
 | • ITB not installed correctly. • ITB   defective • Optical unit installed incorrectly • Optical unit defective | 
        
            | SC272 | Skew Control Upper Lower Limit: CThe pulse total for Cyan skew control is not within the prescribed range.
 | • ITB not installed correctly. • ITB   defective • Optical unit installed incorrectly • Optical unit defective | 
        
            | SC285 | MUSIC Continuous FailureThe MUSIC adjustment failed after four attempts.
 | • Fusing belt installed incorrectly • Fusing   belt surface scoured, scratched • MUSIC sensors dirty, defective | 
        
            | Code | Description | Causes | 
        
            | SC300 | Drum charge corona wire error: KThe output of the charge corona wire of the black PCU is abnormal.
 | • CGB power pack connection loose, broken   defective • Check CGB power pack connection to BCU • CGB power pack defective   • BCU defective • Replace OPC drum | 
        
            | SC301 | AC charge output error: MAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the AC charge for M, C, Y.
 | • Disconnect the high voltage cable from   Terminal C of the multiple high-voltage supply board. • Attach a voltmeter to   the terminal. • If there is no output from the terminal, replace the high   voltage power supply. -or- • If there is output from the terminal, test the   resistance between the high voltage cable and the ground. If resistance is   nearly "0", check the high-voltage harness for defects and replace   it if necessary. • Test the conductivity between the OPC unit and the ground.   If there is no conductivity between the OPC unit and ground, replace the OPC   unit. • If there is no charge PWM signal, replace the harness and/or VBCU. | 
        
            | SC302 | AC charge output error: CAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the AC charge for M, C, Y.
 | • Disconnect the high voltage cable from   Terminal C of the multiple high-voltage supply board. • Attach a voltmeter to   the terminal. • If there is no output from the terminal, replace the high   voltage power supply. -or- • If there is output from the terminal, test the   resistance between the high voltage cable and the ground. If resistance is   nearly "0", check the high-voltage harness for defects and replace   it if necessary. • Test the conductivity between the OPC unit and the ground.   If there is no conductivity between the OPC unit and ground, replace the OPC   unit. • If there is no charge PWM signal, replace the harness and/or VBCU. | 
        
            | SC303 | AC charge output error: YAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the AC charge for M, C, Y.
 | • Disconnect the high voltage cable from   Terminal C of the multiple high-voltage supply board. • Attach a voltmeter to   the terminal. • If there is no output from the terminal, replace the high   voltage power supply. -or- • If there is output from the terminal, test the   resistance between the high voltage cable and the ground. If resistance is   nearly "0", check the high-voltage harness for defects and replace   it if necessary. • Test the conductivity between the OPC unit and the ground.   If there is no conductivity between the OPC unit and ground, replace the OPC   unit. • If there is no charge PWM signal, replace the harness and/or VBCU. | 
        
            | SC304 | Charge Corona   Error: Charge Leak (K PCU)A abnormal detection signal (H) was detected for longer than 250 ms.
 | • Turn the machine power off/on • CGB power   pack harness connectors loose, broken, defective • Corona wire caps loose, missing • CGB power   pack defective • Charge corona unit connectors loose, broken, defective | 
        
            | SC308 | Charge Corona   Error: Wire Cleaner Error (K PCU)The charge corona wire cleaner motor remained locked after the motor was   switched on, or failed to switch off within the prescribed time after   cleaning started.
 | • Turn the machine power off/on • Motor   overloaded due to a physical obstruction • Motor defective | 
        
            | SC313 | Charge, development error: MAfter the M, C, or Y drum started to rotate, the feedback for the charge unit   of the color dropped below 0.3V.
 | • Make sure that the settings of SP2202 are   at the defaults. • Check harness connections between charge roller and   transfer power pack. • Defective charge roller • Defective power pack | 
        
            | SC314 | Charge, development error: CAfter the M, C, or Y drum started to rotate, the feedback for the charge unit   of the color dropped below 0.3V.
 | • Make sure that the settings of SP2202 are   at the defaults. • Check harness connections between charge roller and   transfer power pack. • Defective charge roller • Defective power pack | 
        
            | SC315 | Charge, development error: YAfter the M, C, or Y drum started to rotate, the feedback for the charge unit   of the color dropped below 0.3V.
 | • Make sure that the settings of SP2202 are   at the defaults. • Check harness connections between charge roller and   transfer power pack. • Defective charge roller • Defective power pack | 
        
            | SC316 | Drum Charge Error: KDrum charge output voltage (Vpp) exceeded 2.8 kV.
 | • Check the connections of the charge unit   of the PCU where the problem occurred. • Replace the charge unit of the PCU   (CBG power pack for the K PCU, charge roller unit for YMC PCUs) | 
        
            | SC317 | Drum Charge Error: MDrum charge output voltage (Vpp) exceeded 2.8 kV.
 | • Check the connections of the charge unit   of the PCU where the problem occurred. • Replace the charge unit of the PCU   (CBG power pack for the K PCU, charge roller unit for YMC PCUs) | 
        
            | SC318 | Drum Charge Error: CDrum charge output voltage (Vpp) exceeded 2.8 kV.
 | • Check the connections of the charge unit   of the PCU where the problem occurred. • Replace the charge unit of the PCU   (CBG power pack for the K PCU, charge roller unit for YMC PCUs) | 
        
            | SC319 | Drum Charge Error: YDrum charge output voltage (Vpp) exceeded 2.8 kV.
 | • Check the connections of the charge unit   of the PCU where the problem occurred. • Replace the charge unit of the PCU   (CBG power pack for the K PCU, charge roller unit for YMC PCUs) | 
        
            | SC320 | Development power pack error: KThis SC is issued if the VBCU detects a short in the development DC charge   for K, M, C, Y.
 | • Development power pack defective • High   voltage power supply defective • High voltage power supply harness defective   • Development unit defective • IOB harness disconnected or defective • IOB   defective | 
        
            | SC321 | Development power pack error: MThis SC is issued if the VBCU detects a short in the development DC charge   for K, M, C, Y.
 | • Development power pack defective • High   voltage power supply defective • High voltage power supply harness defective   • Development unit defective • IOB harness disconnected or defective • IOB   defective | 
        
            | Code | Description | Causes | 
        
            | SC322 | Development power pack error: CThis SC is issued if the VBCU detects a short in the development DC charge   for K, M, C, Y.
 | • Development power pack defective • High   voltage power supply defective • High voltage power supply harness defective   • Development unit defective • IOB harness disconnected or defective • IOB   defective | 
        
            | SC323 | Development power pack error: YThis SC is issued if the VBCU detects a short in the development DC charge   for K, M, C, Y.
 | • Development power pack defective • High   voltage power supply defective • High voltage power supply harness defective   • Development unit defective • IOB harness disconnected or defective • IOB   defective | 
        
            | SC324 | Development motor error: KThe PLL lock signal remained HIGH or LOW for longer than the prescribed time   for the K, M, C, or Y, development motor.
 | • Development motor shaft locked, blocked by   obstruction • Development motor defective • DRB defective | 
        
            | SC325 | Development motor error: MThe PLL lock signal remained HIGH or LOW for longer than the prescribed time   for the K, M, C, or Y, development motor.
 | • Development motor shaft locked, blocked by   obstruction • Development motor defective • DRB defective | 
        
            | SC326 | Development motor error: CThe PLL lock signal remained HIGH or LOW for longer than the prescribed time   for the K, M, C, or Y, development motor.
 | • Development motor shaft locked, blocked by   obstruction • Development motor defective • DRB defective | 
        
            | SC327 | Development motor error: YThe PLL lock signal remained HIGH or LOW for longer than the prescribed time   for the K, M, C, or Y, development motor.
 | • Development motor shaft locked, blocked by   obstruction • Development motor defective • DRB defective | 
        
            | SC336 | Developer set error: KThe value of Vcnt is set at the maximum or minimum setting when the TD sensor   is initialized.
 | 1. Open the front door. 2. Pull out the film   seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the   correct SP for the affected color: • SP3801 003 to initialize the TD sensor   for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to   initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for   Y | 
        
            | SC337 | Developer set error: MThe value of Vcnt is set at the maximum or minimum setting when the TD sensor   is initialized.
 | 1. Open the front door. 2. Pull out the film   seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the   correct SP for the affected color: • SP3801 003 to initialize the TD sensor   for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to   initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for   Y | 
        
            | SC338 | Developer set error: CThe value of Vcnt is set at the maximum or minimum setting when the TD sensor   is initialized.
 | 1. Open the front door. 2. Pull out the film   seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the   correct SP for the affected color: • SP3801 003 to initialize the TD sensor   for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to   initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for   Y | 
        
            | SC339 | Developer set error: YThe value of Vcnt is set at the maximum or minimum setting when the TD sensor   is initialized.
 | 1. Open the front door. 2. Pull out the film   seal from the black, magenta, cyan, or yellow developer bottle. 3. Do the   correct SP for the affected color: • SP3801 003 to initialize the TD sensor   for K. • SP3801 004 to initialize the TD sensor for M. • SP3801 005 to   initialize the TD sensor for C. • SP3801 006 to initialize the TD sensor for   Y | 
        
            | SC348 | Toner supply motor error2 sec. after the motor START signal is output, a LOCK signal cannot be   detected.
 | • Motor harness disconnected, loose, or   defective • Toner pump overload • Sub hopper overload • Toner hopper motor   defective | 
        
            | SC350 | Developer Fill Error: KThe PCU failed to fill with developer from the developer bottle when SP3814-1   was executed.
 | • Developer bottle not set correctly •   Developer in the bottle is clogged and not flowing Note: For detailed   information about how to handle problems developer filling, see   "Handling Problems with Developer Filling" under "PCU" in   Section 3. | 
        
            | SC351 | Developer Fill Error: MThe PCU failed to fill with developer from the developer bottle when SP3814-1   was executed.
 | • Developer bottle not set correctly •   Developer in the bottle is clogged and not flowing Note: For detailed   information about how to handle problems developer filling, see   "Handling Problems with Developer Filling" under "PCU" in   Section 3. | 
        
            | SC352 | Developer Fill Error: CThe PCU failed to fill with developer from the developer bottle when SP3814-1   was executed.
 | • Developer bottle not set correctly •   Developer in the bottle is clogged and not flowing Note: For detailed   information about how to handle problems developer filling, see   "Handling Problems with Developer Filling" under "PCU" in   Section 3. | 
        
            | SC353 | Developer Fill Error: YThe PCU failed to fill with developer from the developer bottle when SP3814-1   was executed.
 | • Developer bottle not set correctly •   Developer in the bottle is clogged and not flowing Note: For detailed   information about how to handle problems developer filling, see   "Handling Problems with Developer Filling" under "PCU" in   Section 3. | 
        
            | Code | Description | Causes | 
        
            | SC360 | TD sensor (Vt high) error: KThe Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V   for 10 counts.
 | • Black, magenta, cyan, or yellow TD sensor   disconnected • Harness between TD sensor and PCU defective • Defective TD   sensor, replace the PCU Note: The TD sensor cannot be replaced independently.   The PCU must be replaced if the TD sensor is defective. | 
        
            | SC361 | TD sensor (Vt high) error: MThe Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V   for 10 counts.
 | • Black, magenta, cyan, or yellow TD sensor   disconnected • Harness between TD sensor and PCU defective • Defective TD   sensor, replace the PCU Note: The TD sensor cannot be replaced independently.   The PCU must be replaced if the TD sensor is defective. | 
        
            | SC362 | TD sensor (Vt high) error: CThe Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V   for 10 counts.
 | • Black, magenta, cyan, or yellow TD sensor   disconnected • Harness between TD sensor and PCU defective • Defective TD   sensor, replace the PCU Note: The TD sensor cannot be replaced independently.   The PCU must be replaced if the TD sensor is defective. | 
        
            | SC363 | TD sensor (Vt high) error: YThe Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V   for 10 counts.
 | • Black, magenta, cyan, or yellow TD sensor   disconnected • Harness between TD sensor and PCU defective • Defective TD   sensor, replace the PCU Note: The TD sensor cannot be replaced independently.   The PCU must be replaced if the TD sensor is defective. | 
        
            | SC364 | TD sensor (Vt low) error: KThe Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V   for 10 counts.
 | • TD sensor harness disconnected, loose,   defective • A drawer connector (located on the rear of a development unit)   disconnected, loose, defective • TD sensor defective, replace the PCU Note:   The TD sensor cannot be replaced independently. The PCU must be replaced if the   TD sensor is defective. | 
        
            | SC365 | TD sensor (Vt low) error: MThe Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V   for 10 counts.
 | • TD sensor harness disconnected, loose,   defective • A drawer connector (located on the rear of a development unit)   disconnected, loose, defective • TD sensor defective, replace the PCU Note:   The TD sensor cannot be replaced independently. The PCU must be replaced if   the TD sensor is defective. | 
        
            | SC366 | TD sensor (Vt low) error: CThe Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V   for 10 counts.
 | • TD sensor harness disconnected, loose,   defective • A drawer connector (located on the rear of a development unit)   disconnected, loose, defective • TD sensor defective, replace the PCU Note: The   TD sensor cannot be replaced independently. The PCU must be replaced if the   TD sensor is defective. | 
        
            | SC367 | TD sensor (Vt low) error: YThe Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V   for 10 counts.
 | • TD sensor harness disconnected, loose,   defective • A drawer connector (located on the rear of a development unit)   disconnected, loose, defective • TD sensor defective, replace the PCU Note:   The TD sensor cannot be replaced independently. The PCU must be replaced if   the TD sensor is defective. | 
        
            | SC372 | TD sensor adjustment error: KDuring TD sensor initialization with SP3801, the output value of the black,   magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
 | TD harness sensor disconnected, loose or   defective Harness between TD sensor and drawer disconnected, defective • TD   sensor defective, replace the PCU Note: The TD sensor cannot be replaced   independently. The PCU must be replaced if the TD sensor is defective. | 
        
            | SC373 | TD sensor adjustment error: MDuring TD sensor initialization with SP3801, the output value of the black,   magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
 | TD harness sensor disconnected, loose or   defective Harness between TD sensor and drawer disconnected, defective • TD   sensor defective, replace the PCU Note: The TD sensor cannot be replaced   independently. The PCU must be replaced if the TD sensor is defective. | 
        
            | SC374 | TD sensor adjustment error: CDuring TD sensor initialization with SP3801, the output value of the black,   magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
 | TD harness sensor disconnected, loose or   defective Harness between TD sensor and drawer disconnected, defective • TD   sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently.   The PCU must be replaced if the TD sensor is defective. | 
        
            | SC375 | TD sensor adjustment error: YDuring TD sensor initialization with SP3801, the output value of the black,   magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
 | TD harness sensor disconnected, loose or   defective Harness between TD sensor and drawer disconnected, defective • TD   sensor defective, replace the PCU Note: The TD sensor cannot be replaced   independently. The PCU must be replaced if the TD sensor is defective. | 
        
            | SC396 | Drum motor error: KThe motor is trying to rotate at power on or during normal operation but   there is an excessive load on the drum shaft. The motor has no traction (due   to a bent cleaning blade, for example).
 | • Drum motor harness loose, broken,   defective • Drum motor defective • DTMB defective | 
        
            | SC397 | Drum motor error: MThe motor is trying to rotate at power on or during normal operation but   there is an excessive load on the drum shaft. The motor has no traction (due   to a bent cleaning blade, for example).
 | • Drum motor harness loose, broken,   defective • Drum motor defective • DTMB defective | 
        
            | SC398 | Drum motor error: CThe motor is trying to rotate at power on or during normal operation but   there is an excessive load on the drum shaft. The motor has no traction (due   to a bent cleaning blade, for example).
 | • Drum motor harness loose, broken,   defective • Drum motor defective • DTMB defective | 
        
            | Code | Description | Causes | 
        
            | SC399 | Drum motor error: YThe motor is trying to rotate at power on or during normal operation but   there is an excessive load on the drum shaft. The motor has no traction (due   to a bent cleaning blade, for example).
 | • Drum motor harness loose, broken,   defective • Drum motor defective • DTMB defective | 
        
            | SC400 | ID sensor error: CalibrationBefore adjustment Vsg_reg<0.5 but Vsg_reg could not be adjusted to the   target Vsg_reg = 4.0+-0.2V during process control.
 | • ID sensor harness disconnected, loose,   defective • ID sensor dirty • ID sensor defective • ITB unit drawer connector   dirty | 
        
            | SC410 | ID sensor error: Development KDevelopment gamma for black, magenta, cyan, or yellow is not within range   (0.3 to 6.0). Process control halts when this SC is issued.
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken,   defective • Potential sensor defective • LD unit not firing • ITB separation   for CMY abnormal • Transfer power pack defective) | 
        
            | SC411 | ID sensor error: Development MDevelopment gamma for black, magenta, cyan, or yellow is not within range   (0.3 to 6.0). Process control halts when this SC is issued.
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken,   defective • Potential sensor defective • LD unit not firing • ITB separation   for CMY abnormal • Transfer power pack defective) | 
        
            | SC412 | ID sensor error: Development CDevelopment gamma for black, magenta, cyan, or yellow is not within range   (0.3 to 6.0). Process control halts when this SC is issued.
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken,   defective • Potential sensor defective • LD unit not firing • ITB separation   for CMY abnormal • Transfer power pack defective) | 
        
            | SC413 | ID sensor error: Development YDevelopment gamma for black, magenta, cyan, or yellow is not within range   (0.3 to 6.0). Process control halts when this SC is issued.
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • LD sensor harness loose, broken,   defective • Potential sensor defective • LD unit not firing • ITB separation   for CMY abnormal • Transfer power pack defective) | 
        
            | SC414 | ID sensor error: Development start voltage KThe development start voltage in the development of the black, magenta, cyan,   or yellow PCU is not within the correct range (+-150V)
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit   not firing • ITB separation for CMY abnormal • Transfer power pack defective | 
        
            | SC415 | ID sensor error: Development start voltage MThe development start voltage in the development of the black, magenta, cyan,   or yellow PCU is not within the correct range (+-150V)
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit   not firing • ITB separation for CMY abnormal • Transfer power pack defective | 
        
            | SC416 | ID sensor error: Development start voltage CThe development start voltage in the development of the black, magenta, cyan,   or yellow PCU is not within the correct range (+-150V)
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit   not firing • ITB separation for CMY abnormal • Transfer power pack defective | 
        
            | SC417 | ID sensor error: Development start voltage YThe development start voltage in the development of the black, magenta, cyan,   or yellow PCU is not within the correct range (+-150V)
 | • Toner density abnormal. Refer to the image   troubleshooting section in Section 4 of the Venus-C1 B132 Service Manual   (Self-Check Error Codes 55 to 59, 61). • Potential sensor defective • LD unit   not firing • ITB separation for CMY abnormal • Transfer power pack defective | 
        
            | SC418 | LED error during Vsg adjustmentPWM value: Ifsg>3000 This means the current to the LED of the ID sensor is   abnormal.
 | • ID sensor dirty • ID sensor defective | 
        
            | SC420 | Potential sensor error: Vd Adjustment KThe development potential of the drum before exposure (Vd) cannot be adjusted   to within +-8 V of the target voltage (-900V).
 | • Drum potential sensor harness, connector   is loose, broken, defective • Drum potential sensor dirty • Drum potential   sensor defective • Drum connector, harness loose, broken, defective •   Development power pack defective • VBCU defective | 
        
            | SC421 | Potential sensor error: Vd Adjustment KThe development potential of the drum before exposure (Vd) cannot be adjusted   to within +-8 V of the target voltage (-900V).
 | • Drum potential sensor harness, connector   is loose, broken, defective • Drum potential sensor dirty • Drum potential   sensor defective • Drum connector, harness loose, broken, defective •   Development power pack defective • VBCU defective | 
        
            | SC422 | Potential sensor error: Vd Adjustment MThe development potential of the drum before exposure (Vd) cannot be adjusted   to within +-8 V of the target voltage (-900V).
 | • Drum potential sensor harness, connector   is loose, broken, defective • Drum potential sensor dirty • Drum potential   sensor defective • Drum connector, harness loose, broken, defective •   Development power pack defective • VBCU defective | 
        
            | SC423 | Potential sensor error: Vd Adjustment CThe development potential of the drum before exposure (Vd) cannot be adjusted   to within +-8 V of the target voltage (-900V).
 | • Drum potential sensor harness, connector   is loose, broken, defective • Drum potential sensor dirty • Drum potential   sensor defective • Drum connector, harness loose, broken, defective •   Development power pack defective • VBCU defective | 
        
            | Code | Description | Causes | 
        
            | SC423 | Potential sensor error: Vd Adjustment YThe development potential of the drum before exposure (Vd) cannot be adjusted   to within +-8 V of the target voltage (-900V).
 | • Drum potential sensor harness, connector   is loose, broken, defective • Drum potential sensor dirty • Drum potential   sensor defective • Drum connector, harness loose, broken, defective •   Development power pack defective • VBCU defective | 
        
            | SC424 | Potential sensor error 5: Vl adjustment KVpl could not be adjusted to within +-5V of the target Vpl after exposure of   the ID sensor patterns.
 | • Drum worn • LD unit dirty • Poor drum   ground connection | 
        
            | SC425 | Potential sensor error 6: Vl adjustment MVpl could not be adjusted to within +-5V of the target Vpl after exposure of   the ID sensor patterns.
 | • Drum worn • LD unit dirty • Poor drum   ground connection | 
        
            | SC426 | Potential sensor error 7: Vl adjustment CVpl could not be adjusted to within +-5V of the target Vpl after exposure of   the ID sensor patterns.
 | • Drum worn • LD unit dirty • Poor drum   ground connection | 
        
            | SC427 | Potential sensor error 8: Vl adjustment YVpl could not be adjusted to within +-5V of the target Vpl after exposure of   the ID sensor patterns.
 | • Drum worn • LD unit dirty • Poor drum   ground connection | 
        
            | SC432 | Potential sensor error 1: Vr KVr > 200V. The residual voltage (Vr), the amount of voltage that remains   on the surface of the drum after the QL fires is greater than 200V.
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC433 | Potential sensor error 2: Vr MVr > 200V. The residual voltage (Vr), the amount of voltage that remains   on the surface of the drum after the QL fires is greater than 200V.
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC434 | Potential sensor error 3: Vr CVr > 200V. The residual voltage (Vr), the amount of voltage that remains   on the surface of the drum after the QL fires is greater than 200V.
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC435 | Potential sensor error 4: Vr YVr > 200V. The residual voltage (Vr), the amount of voltage that remains   on the surface of the drum after the QL fires is greater than 200V.
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC436 | Potential sensor error: Vd KThe VdHome reading, the first step of the process control self-check,   detected that the development potential of the unexposed areas of the drum   are not within the prescribed range (-500 to -800)
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC437 | Potential sensor error: Vd MThe VdHome reading, the first step of the process control self-check,   detected that the development potential of the unexposed areas of the drum   are not within the prescribed range (-500 to -800)
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC438 | Potential sensor error: Vd CThe VdHome reading, the first step of the process control self-check,   detected that the development potential of the unexposed areas of the drum   are not within the prescribed range (-500 to -800)
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC439 | Potential sensor error: Vd YThe VdHome reading, the first step of the process control self-check,   detected that the development potential of the unexposed areas of the drum   are not within the prescribed range (-500 to -800)
 | • Potential sensor dirty • Potential sensor   defective • Charge roller defective • Charge power pack defective • OPC   defective | 
        
            | SC440 | Image transfer power pack error: KAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the power pack for K, M, C, or Y.
 | • Transfer belt damaged, insulation damaged   • Insulation on high voltage cable damaged • Another hot point inside the   machine has damaged insulation • Insulation around high-voltage power supply   damaged | 
        
            | SC441 | Image transfer power pack error: MAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the power pack for K, M, C, or Y.
 | • Transfer belt damaged, insulation damaged   • Insulation on high voltage cable damaged • Another hot point inside the   machine has damaged insulation • Insulation around high-voltage power supply   damaged | 
        
            | Code | Description | Causes | 
        
            | SC442 | Image transfer power pack error: CAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the power pack for K, M, C, or Y.
 | • Transfer belt damaged, insulation damaged   • Insulation on high voltage cable damaged • Another hot point inside the   machine has damaged insulation • Insulation around high-voltage power supply   damaged | 
        
            | SC443 | Image transfer power pack error: YAn interrupt checks the status of the power pack every 10 ms. This SC is   issued if the VBCU detects a short in the power pack for K, M, C, or Y.
 | • Transfer belt damaged, insulation damaged   • Insulation on high voltage cable damaged • Another hot point inside the machine   has damaged insulation • Insulation around high-voltage power supply damaged | 
        
            | SC445 | Image transfer motor errorThe control board of the ITB motor belt generated signals that indicate there   is problem with the image transfer belt motor.
 | • ITB motor defective • ITB control board   defective • ITB overloaded • Encoder strip on the edge of the ITB damaged. | 
        
            | SC446 | ITB lift motor errorThe state of the ITB lift sensor does not change its state (switching from   off to on or vice versa), even after the ITB lift motor starts rotating.
 | • ITB lift sensor dirty, disconnected,   defective • ITB lift motor disconnected, defective • ITB sensor defective •   ITB lift motor defective | 
        
            | SC447 | Image transfer roller position errorThe machine checks for the presence of the K STC and the checks the status of   the K image transfer roller lift sensor after the door is closed.
 | • Transfer belt release lever down • Lift   sensor connector loose, broken, dirty • Lift sensor defective | 
        
            | SC450 | Transfer power pack output errorAn interrupt checks the status of the power pack every 2 ms. This SC is   issued if the VBCU detects a short in the power pack 250 times at T2 within   500 ms.
 | • Damaged insulation on the high-voltage   supply cable • Damaged insulation around the highvoltage power supply. • Check   SIOB harness connections • SIOB defective | 
        
            | SC452 | PTR lift mechanism errorThe PTR was not detected at the home position within 2 sec. after the PTR   lift motor turned on.
 | • PTR HP sensor dirty, disconnected,   defective • PTR lift motor disconnected, defective | 
        
            | SC455 | PTR motor errorThe lock signal from the paper transfer motor was not detected within 1 sec.   after the motor switched on.
 | • Motor disconnected • PTR shaft locked,   needs cleaning, blocked by obstruction • Drive shaft of the ITB locked and   overloaded, needs cleaning, or blocked by obstruction • DRB disconnected,   defective | 
        
            | SC460 | Separation power pack output errorThis SC is issued if the VBCU detects a short in the transfer power pack.
 | • Damaged insulation on the high-voltage   supply cable (replace cable) • Damaged insulation around the transfer power   pack | 
        
            | SC465 | Image Transfer Roller End: KThe machine detected an abnormal reading of the resistance of the transfer   roller because it is near the end of its service life.
 | • Check the connections between the transfer   roller power pack the roller • Replace image transfer roller • Image transfer   power pack defective | 
        
            | SC466 | Image Transfer Roller End: MThe machine detected an abnormal reading of the resistance of the transfer   roller because it is near the end of its service life.
 | • Check the connections between the transfer   roller power pack the roller • Replace image transfer roller • Image transfer   power pack defective | 
        
            | SC467 | Image Transfer Roller End: CThe machine detected an abnormal reading of the resistance of the transfer   roller because it is near the end of its service life.
 | • Check the connections between the transfer   roller power pack the roller • Replace image transfer roller • Image transfer   power pack defective | 
        
            | SC468 | Image Transfer Roller End: YThe machine detected an abnormal reading of the resistance of the transfer   roller because it is near the end of its service life.
 | • Check the connections between the transfer   roller power pack the roller • Replace image transfer roller • Image transfer   power pack defective | 
        
            | SC472 | ITB Bias Roller EndThe machine detected an abnormal reading of the resistance of the ITB bias   roller because it is near the end of its service life.
 | • Check the connections between the transfer   power pack • Replace image transfer roller • Transfer power pack defective | 
        
            | SC480 | Drum cleaning motor error: KThe drum cleaning motor failed to switch on (motor lock), or failed to reach   the required speed within the prescribed time.
 | • Motor block by physical obstruction •   Motor harness loose, broken, defective • Motor defective | 
        
            | Code | Description | Causes | 
        
            | SC481 | Drum cleaning motor error: MThe drum cleaning motor failed to switch on (motor lock), or failed to reach   the required speed within the prescribed time.
 | • Motor block by physical obstruction •   Motor harness loose, broken, defective • Motor defective | 
        
            | SC482 | Drum cleaning motor error: CThe drum cleaning motor failed to switch on (motor lock), or failed to reach   the required speed within the prescribed time.
 | • Motor block by physical obstruction •   Motor harness loose, broken, defective • Motor defective | 
        
            | SC483 | Drum cleaning motor error: YThe drum cleaning motor failed to switch on (motor lock), or failed to reach   the required speed within the prescribed time.
 | • Motor block by physical obstruction •   Motor harness loose, broken, defective • Motor defective | 
        
            | SC484 | Used toner bottle fullThe toner full sensor has detected that the used toner bottle is full.
 | • Remove the used toner bottle • Empty the   used toner bottle and reinstall it | 
        
            | SC485 | Used toner bottle motor errorThe lock signal of the used toner bottle motor remains HIGH for more than 600   ms.
 | • Used toner bottle harness loose, broken,   defective • Used toner bottle motor defective | 
        
            | SC487 | Used toner bottle set errorThe set sensor of the used toner bottle remains LOW for more than 500 ms.   (The sensor goes HIGH when the bottle is installed correctly.)
 | • Used toner bottle not installed • Remove   used toner bottle and reinstall correctly | 
        
            | SC488 | Used toner transport lockUsed toner cannot be transported to the used toner bottle.
 | • Blockage in the line to the used toner   bottle | 
        
            | SC490 | MUSIC sensor errorOne or more of the MUSIC sensors is not functioning normally.
 | • MUSIC sensor harness loose, broken,   defective • Sensor defective | 
        
            | SC495 | ITB encoder sensor errorThe ITB encoder sensor that reads the encoded strip on the ITB is not   functioning properly.
 | • Sensor dirty • Sensor harness loose,   broken, defective • Sensor out of position because installed incorrectly •   ITB installed incorrectly | 
        
            | SC496 | MUSIC sensor errorThe MUSIC sensor detected an abnormal pattern on the ITB because: • ADC   exceeded upper or lower limit. • The pattern used to calculate the amount of   skew is abnormal. • The reading of the pattern exceeded the length of time   the LED projected light. • LED light could not be adjusted correctly.
 | • ITB installed incorrectly • Inspect ITB   belt for damage, replace • MUSIC pattern abnormal; do a forced process   control (SP3821) and check the result. • MUSIC sensor defective or   disconnected | 
        
            | SC497 | Temperature and humidity sensor error: M PCUThe thermistor output of the temperature and humidity sensor above the M PCU   was not within the prescribed range (0.5V to 4.2V)
 | • Temperature and humidity sensor harness   disconnected, loose, defective • Temperature and humidity sensor defective | 
        
            | SC498 | Temperature and humidity sensor error: Toner   BottleThe thermistor output of the temperature and humidity sensor below the used   toner bottle was not within the prescribed range (0.5V to 4.2V)
 | • Temperature and humidity sensor harness   disconnected, loose, defective • Temperature and humidity sensor defective | 
        
            | SC499 | ITB encoder sensor error The ITB sensor that   reads the encoded film strip on the edge of the image transfer belt is   sending is operating correctly. | • ITB encoder sensor dirty • Sensor harness   disconnected or damaged • Encoded scale on the edge of the ITB is damaged or   dirty • ITB installed incorrectly | 
        
            | SC501 | Tray 1 (tandem tray) feed error (Japan Only)The tray 1 lift sensor does not switch on 10 s after the tray lift motor   switches on and starts lifting the bottom plate. When the tray lowers, the   tray lift sensor does not go off within 1.5 sec. The lower limit sensor of   the tandem tray does not detect the lower limit within 10 sec.
 | • Tray lift motor harness disconnected,   loose, defective • Paper or other obstacle trapped between tray and motor •   Tray lift sensor disconnected, damaged • Lower limit sensor disconnected,   damaged • Pick-up solenoid disconnected, blocked by an obstacle | 
        
            | SC502 | Tray 2 (paper cassette) feed error (Japan   Only)The lift sensor is not activated within 10 seconds after the tray lift motor   starts lifting the bottom plate. When the tray lowers, the tray lift sensor   does not go off within 1.5 sec. The lower limit sensor of the tandem tray   does not detect the lower limit within 10 sec.
 | • Tray lift motor defective or disconnected   • Paper or other obstacle trapped between tray and motor • Pick-up solenoid   disconnected or blocked by an obstacle | 
        
            | Code | Description | Causes | 
        
            | SC503 | Tray 1 feed errorThe lift sensor is not activated within 10 seconds after the tray lift motor   starts lifting the bottom plate. When the tray lowers, the tray lift sensor   does not go off within 1.5 sec.
 | • Tray lift motor defective or disconnected   • Paper or other obstacle trapped between tray and motor • Pick-up solenoid   disconnected or blocked by an obstacle | 
        
            | SC504 | Tray 2 feed errorThe lift sensor is not activated within 10 seconds after the tray lift motor   starts lifting the bottom plate. When the tray lowers, the tray lift sensor   does not go off within 1.5 sec.
 | • Tray lift motor defective or disconnected   • Paper or other obstacle trapped between tray and motor • Pick-up solenoid   disconnected or blocked by an obstacle | 
        
            | SC505 | Tandem tray rear fence motor errorThe return sensor does not switch on within 10 sec. after the rear fence   motor switches on. The HP sensor does not switch on 10 sec. after the rear   fence motor switches on. The HP sensor and return sensor switch on at the   same time.
 | • Rear fence motor defective or poor   connection • Paper or other obstacle interfering with operation of the   sensors • Paper or other obstacle trapped between tray and motor • Motor   mechanical overload due to obstruction • Return sensor or HP sensor defective   or dirty | 
        
            | SC510 | LCT tray error: B473/D350When the bottom plate is lifted, the upper limit sensor does not come on for   30 sec. When the bottom plate is lowered, the lower limit sensor does not   come on for 30 sec. After lift begins, the upper limit sensor does not switch   on before the pick-up solenoid switches on. The paper end sensor switches on   during lift and the upper limit sensor does not switch on for 2.5 s, and a   message prompts user to reset paper.
 | • Tray lift motor harness, disconnected,   loose, or defective • Tray lift motor defective • Lift sensor defective or   disconnected • Pick-up solenoid defective or disconnected • Paper end sensor   defective | 
        
            | SC515 | Duplex jogger motor error 1When the jogger fence moves to the home position, the jogger fence HP sensor   does not switch on even after the jogger motor has moved the jogger fence   153.5 mm.
 | • Jogger fence motor defective or poor   connection • Paper or other obstacle interfering with operation of the   sensors or motor • Return sensor or HP sensor defective, dirty, or   disconnected • Paper or other obstacle has jammed mechanism • HP sensor   connector disconnected or defective • HP sensor defective | 
        
            | SC516 | Duplex jogger motor error 2When the jogger fence moves from the home position, the jogger fence HP   sensor does not turn off even if the jogger motor has moved the jogger fence   153.5 mm.
 | • Jogger fence motor defective or poor   connection • Paper or other obstacle interfering with operation of the   sensors or motor • Return sensor or HP sensor defective, dirty, or   disconnected • Paper or other obstacle has jammed mechanism • HP sensor   connector disconnected or defective • HP sensor defective | 
        
            | SC517 | LCIT air assist front fan errorThe front air assist fan is not functioning properly.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged, defective | 
        
            | SC518 | LCIT air assist rear fan errorThe rear air assist fan is not functioning properly.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged, defective | 
        
            | SC530 | Fusing cooling fan errorThe VBCU did not receive the lock signal 5 seconds after the fusing unit fan   switches on.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC531 | Fusing Fan Error: FrontThe lock signal remained HIGH for 5 sec. while the fan at the front of the   fusing unit near the heat dissipation fins was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC532 | Controller fan errorThe lock signal remained HIGH for 5 sec. while the fan that cools the printed   circuit boards was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC533 | Fusing unit suction fan errorThe lock signal remained HIGH for 5 sec. while the fan that draws air out of   the fusing unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC534 | Duplex unit fan errorThe lock signal remained HIGH for 5 sec. while the fan that draws air out of   the duplex unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC535 | Development Intake Fan ErrorThe lock signal remained HIGH for 5 sec. while the fan in the Y development   unit was operating
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC536 | Development Intake Fan Error: YThe lock signal remained HIGH for 5 sec. while the fan in the development   unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | Code | Description | Causes | 
        
            | SC537 | Development Intake Fan Error: CThe lock signal remained HIGH for 5 sec. while the fan in the development   unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC538 | Development Intake Fan Error: MThe lock signal remained HIGH for 5 sec. while the fan in the development   unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC539 | Development Intake Fan Error: KThe lock signal remained HIGH for 5 sec. while the fan in the development   unit was operating.
 | • Fan harness disconnected or damaged • Fan   blocked by an obstruction • Fan damaged | 
        
            | SC540 | Fusing/exit motor errorMotor operation was detected abnormal at power on.
 | • Check inside the fusing unit for any   obstructions • Motor harness loose, broken, defective • Motor or its driver   board defective | 
        
            | SC541 | Heating roller thermistor (center) error 1The "floating" (non-contact) thermistor at the center of the   heating roller is not operating correction.
 | • Thermistor harness connection loose,   disconnected, defective • Thermistor installed incorrectly • Thermistor   defective | 
        
            | SC543 | Heating roller thermistor (center) error 2The thermistor at the center of the heating roller detected an abnormally   high temperature (over 250°C)
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC544 | Heating roller thermistor (center) error 3The thermistor detected a temperature over 260°C..
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC545 | Lamp remains onAfter hot roller reaches warm-up temperature, the center fusing lamps in the   heating roller remained on at full capacity after reaching the warm-up   temperature while the hot roller was not rotating.
 | • Do SP5810 to cancel the SC fusing code. •   Heating roller thermistor damaged, or out of position • Fusing lamp   disconnected, broken | 
        
            | SC546 | Heating roller thermistor error (side)The temperature measured by the heating roller thermistor does not reach 0°C   after 50 sec. and remains over this temperature for 10 readings.
 | • Loose connection of the heating roller   thermistor • Defective heating roller thermistor | 
        
            | SC547 | Zero cross errorWhen the main switch is turned on, the machine checks how many zero-cross   signals are generated within 500 ms. This SC code is issued if the number of   zero-cross signals detected is not within specification. Note: Zero cross   signals, generated from an ac power supply, are used to generate a trigger pulses   to control the applied power accurately.
 | • Do SP5810 to cancel the SC fusing code. •   Electrical noise on the power supply line • Fusing relay damaged, replace the   AC drive board. | 
        
            | SC549 | Heating roller thermistor (center): software   errorThe thermistor detected a temperature over 250°C 10 times within 1 sec.
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC550 | Heating roller thermistor 3 (side): hardware   errorThe thermistor detected a temperature over 260°C.
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC551 | Pressure roller thermistor error 1The temperature measured by the pressure roller thermistor did not reach 0°C   after 10 attempts.
 | • Do SP5810 to cancel the SC fusing code. •   Loose connection of the pressure roller thermistor • Thermistor positioned   incorrectly • Defective pressure roller thermistor | 
        
            | SC552 | Pressure roller thermistor error 2After the main switch is turned on or the cover is closed, the heating roller   temperature did not reach the ready temperature (45°C) within 80 sec. after   the fusing lamp switches on. -or- If the fusing unit did not reach the reload   temperature after 350 sec.
 | • Pressure roller thermistor harness loose,   disconnected, defective • Pressure roller thermistor defectives. | 
        
            | SC553 | Pressure roller thermistor (software) errorThe thermistor detected a temperature over 220°C 12 times within 1 sec.
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | Code | Description | Causes | 
        
            | SC554 | Pressure roller thermistor (hardware) errorThe thermistor detected a temperature over 230°C.
 | • Do SP5810 to cancel the SC fusing code •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC555 | Pressure roller fusing lamp remains onAfter hot roller reaches warm-up temperature, the pressure roller fusing lamp   remained for 300 sec. while the hot roller is not rotating.
 | • Do SP5810 to cancel the SC fusing code. •   Thermistor damaged, or out of position • Fusing lamp disconnected, broken | 
        
            | SC556 | Heating roller fusing lamp errorAfter hot roller reaches warmup temperature, the heating roller fusing lamp   (ends) remains for 10 sec. while the hot roller is not rotating.
 | • Thermistor damaged, or out of position •   Fusing lamp disconnected, broken | 
        
            | SC557 | Zero Cross Over ErrorAt power on the fusing relay was detected as defective.
 | • Replace the AC drive board. | 
        
            | SC559 | Three Successive Paper Jams in Fusing UnitThis SC only occurs if SP1159 is on, and a jam occurred in the fusing unit   for three consecutive sheets of paper. With SP1159 set to "1" the   machine operation can be restored only by the service technician. The paper   cooling job time sensor detected paper late for 3 counts.
 | • Remove the paper that is jammed in the   fusing unit. • Make sure that the fusing unit is clean and has no obstacles   in the paper feed path. | 
        
            | SC561 | Heating roller non-contact thermistor error   1The temperature measured by the heating roller thermistor (non-contact) on   the end of the heating roller did not reach the prescribed warm-up   temperature within 1 sec.
 | • Loose, broken, damaged connector •   Defective thermistor | 
        
            | SC562 | Heating roller non-contact thermistor error   2After the main switch is turned on or the cover is closed, the heating roller   temperature does not reach the ready temperature within 100 sec. after the   heater switches on. -or- The heating roller did not reach the ready   temperature within 150 sec.
 | • Do SP5810 to cancel the SC fusing code •   Defective hot roller thermistor • Heating roller disconnected, defective | 
        
            | SC563 | Heating roller non-contact thermistor error   3The thermistor 2 (of the heating roller) detected a temperature over 250°C 10   times within 1 sec.
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC564 | Heating roller non-contact thermistor error   3The thermistor detected a temperature over 260°C.
 | • Do SP5810 to cancel the SC fusing code. •   TRIAC short, AC drive board defective • VBCU defective | 
        
            | SC565 | Heating roller fusing lamp on errorAfter fusing belt reached warm-up temperature, the heating roller fusing lamp   remained on for 20 sec. while the hot roller was not rotating.
 | • Do SP5810 to cancel the SC fusing code. •   Thermistor damaged, or out of position • Fusing lamp disconnected, broken | 
        
            | SC568 | Pressure roller lift error 1Even after the leading edge of the paper reached the fusing exit sensor, the   pressure roller lift motor did not raise the pressure roller.
 | • Pressure roller lift sensor connection   loose, broken, damaged • Clean the pressure roller lift sensor • Pressure   roller lift harness loose, broken, damage • Pressure roller lift motor   blocked by an obstruction • Pressure roller lift motor defective | 
        
            | SC569 | Pressure roller lift error 2Pressure roller lift motor not operating correctly. (No signal to indicate   completion of operation.)
 | • Pressure roller lift sensor connection   loose, broken, damaged • Clean the pressure roller lift sensor • Pressure   roller lift harness loose, broken, damage • Pressure roller lift motor   blocked by an obstruction • Pressure roller lift motor defective | 
        
            | SC570 | Development intake fan errorFan motor not operating correctly.
 | • Fan harness loose, broken, defective • Fan   overload due to physical obstruction • Fan motor defective | 
        
            | SC571 | Ozone exhaust fan (FC) errorThe fan of the middle ozone filter box not operating correctly.
 | • Fan harness loose, broken, defective • Fan   overload due to physical obstruction • Fan motor defective | 
        
            | SC572 | Ozone exhaust fan (K) errorThe fan of the lower ozone filter box not operating correctly.
 | • Fan harness loose, broken, defective • Fan   overload due to physical obstruction • Fan motor defective | 
        
            | Code | Description | Causes | 
        
            | SC573 | Ozone intake fan errorThe ozone filter intake fan not operating correctly.
 | • Fan harness loose, broken, defective • Fan   overload due to physical obstruction • Fan motor defective | 
        
            | SC574 | Y thermistor error The thermistor near the Y   PCU has short circuited or otherwise not operating correctly. | • Harness loose, broken, defective •   Thermistor defective | 
        
            | SC599 | Tray 1 lift motor errorAn error was detected in the operation of the lift motor for Tray 1 (tandem   tray).
 | • Motor harness loose, broken, defective •   Motor overload due to an obstruction • Motor defective | 
        
            | SC620 | ARDF communication errorA BREAK signal occurs after the machine detects the ARDF, or a communication   timeout occurs.
 | • ARDF disconnected • VBCU board harness   disconnected, defective • VBCU board defective • Spurious noise from the   power supply line • ARDF defective | 
        
            | SC621 | Mailbox-to-Finisher communication errorCommunication between the mailbox and finisher is interrupted. An ACK/NCK   signal was not received within 100 ms after a data frame is sent and 3   retries failed.
 | • Connection cable between mailbox and   finisher disconnected, defective • Finisher main board defective • VBCU   defective • PSU defective | 
        
            | SC622 | PFB communication errorCommunication between the VBCU and PFB was interrupted. (Communication status   is monitored at 30 ms intervals.)
 | • Connection cable between the VBCU and PFB   is disconnected, defective • VBCU defective • PFB defective | 
        
            | SC624 | Mailbox-to-copier communication errorCommunication between the mailbox and copier is interrupted. An ACK/NCK   signal was not received within 100 ms after a data frame is sent and 3 retries   failed.
 | • Mailbox cable disconnected, defective •   Mailbox main board defective • VBCU defective • PSU defective | 
        
            | SC625 | VBCU-DTMB (DMC1) communication errorCommunication between the VBCU and DMC (main) was interrupted. An ACK/NAK   signal was not received within 100 ms after a data frame was sent and three   retries failed.
 | • Check the DTMB harness connections at the   DTMB and VBCU • DTMB defective • PSU defective • VBCU defective • 5V power   supply defective | 
        
            | SC626 | VBCU-DTMB (DMC2) communication errorCommunication between the VBCU and DMC (sub) was interrupted. An ACK/NAK   signal was not received within 100 ms after a data frame was sent and three   retries failed.
 | • Check the DTMB harness connections at the   DTMB and VBCU • DTMB defective • VBCU defective • PSU defective | 
        
            | SC627 | VBCU-DTMB (TMC) communication errorCommunication between the VBCU and TMC was interrupted. An ACK/NAK signal was   not received within 100 ms after a data frame was sent and three retries   failed.
 | • DTMB harness loose, broken, defective •   DTMB defective • VBCU defective • PSU defective | 
        
            | SC687 | Memory address command errorThe VBCU does not receive a memory address command from the controller 120   seconds after paper is in the position for registration.
 | • Turn the machine power off/on • Check the   controller board connections • Controller defective | 
        
            | SC701 | ARDF original pickup operation errorEven though the pickup motor is rotating clock-wise, the pickup roller home   position sensor cannot detect the position of the pickup roller.
 | • Pickup roller HP sensor harness loose,   disconnected, defective • Pickup roller HP sensor defective • Pickup motor   harness loose, disconnected, defective • Pickup motor defective • ARDF   control board defective | 
        
            | SC705 | ARDF bottom plate lift motorThe bottom plate HP sensor did not detect the home position of the bottom   plate after the bottom plate lift motor switches on and lowers the bottom   plate. The bottom plate position sensor does not detect the position of the   plate after the lift motor switches on and raises the bottom plate.
 | • ARDF feed motor disconnected, defective •   Bottom plate HP sensor disconnected, defective • ARDF main board defective | 
        
            | SC720 | Finisher lower transport motor errorNo encoder pulse signal is detected for the transport motor within the   prescribed time. The 1st failure causes an original jam message, and the 2nd   failure causes this SC code.
 | • Lower transport motor disconnected,   defective • Finisher connection to transport motor loose, defective • Lower   transport motor defective • Finisher main board defective | 
        
            | SC721 | Finisher jogger motor error (D373/D374,   B830)The jogger fences move out of the home position but the HP sensor output does   not change within the specified number of pulses. The 1st failure causes an   original jam message, and the 2nd failure causes this SC code.
 | • Jogger HP sensor disconnected, defective •   Jogger motor disconnected, defective • Jogger motor overloaded due to   obstruction • Finisher main board and jogger motor connection loose,   defective • Finisher main board defective | 
        
            | Code | Description | Causes | 
        
            | SC723 | Finisher feed-out motor (B830)The stack feed-out belt HP sensor does not activate within the specified time   after the stack feedout belt motor turns on. The 1st detection failure causes   a jam error, and the 2nd failure causes this SC code.
 | • Stack feed-out HP sensor disconnected,   defective • Feed-out motor disconnected, defective • Finisher main board   connection to feed out motor disconnected, defective • Motor overload due to   obstruction | 
        
            | SC724 | Finisher stapler hammer motor error (B830)Stapling does not finish within the prescribed time after the staple hammer   motor turns on. The 1st detection failure causes a jam error, and the 2nd   failure causes this SC code.
 | • Stapler hammer motor overloaded due to   obstruction, jammed staple, number of sheets exceeds limit for stapling •   Stapler hammer motor disconnected, defective • Staple hammer motor HP sensor   disconnected, defective | 
        
            | SC725 | Finisher exit guide plate motor error   (D373/D374, B830, B660)After moving away from the guide plate position sensor, the exit guide is not   detected at the home position within the prescribed time. The 1st detection   failure causes a jam error, and the 2nd failure causes this SC code.
 | • Guide plate motor disconnected, defective   • Guide plate motor overloaded due to obstruction • Guide plate position   sensor disconnected, defective | 
        
            | SC726 | Shift jogger motor 1 error (D373/D374, B830)The sides fences do not retract within the prescribed time after the shift   jogger motor switches on. The 1st detection failure causes a jam error, and   the 2nd failure causes this SC code
 | • Shift jogger motor disconnected, defective   • Shift jogger motor overloaded due to obstruction • Shift jogger HP sensor   disconnected, defective | 
        
            | SC727 | Shift jogger motor 2 error (D373/D374)The side fences do not retract within the prescribed time after the shift   jogger motor switches on. The 1st detection failure causes a jam error, and   the 2nd failure causes this SC code.
 | • Motor harness disconnected, loose,   defective • Motor defective • Motor overload • HP defective | 
        
            | SC728 | Shift jogger retraction motor error   (D373/D374)The side fences do not retract within the prescribed time after the   retraction motor switches on. The 1st detection failure causes a jam error,   and the 2nd failure causes this SC code.
 | • Motor harness disconnected, loose,   defective • Motor defective • Motor overload • HP defective | 
        
            | SC730 | Finisher Tray 1 shift motor error (B830)The shift roller HP sensor of the upper tray does not activate within the   prescribed time after the shift tray starts to move toward or away from the   home position. The 1st detection failure causes a jam error, and the 2nd   failure causes this SC code.
 | • Shift tray HP sensor of the upper tray   disconnected, defective • Shift tray motor of the upper tray is disconnected,   defective • Shift tray motor of the upper tray overloaded due to obstruction | 
        
            | SC731 | Upper Transport Motor Error (Proof Tray):   B830No encoder pulse signal is detected for the upper transport motor within 600   ms. The 1st failure causes this SC code.
 | • Upper transport motor disconnected,   defective • Finisher connection to upper transport motor loose, defective •   Upper transport motor blocked by an obstruction • Upper transport motor   defective • Finisher main board defective | 
        
            | SC732 | Shift Tray Exit Motor: 3K Finisher B830The shift tray exit motor is not operating.
 | • Motor harness loose, broken, defective •   Motor is blocked by an obstruction • Motor defective • Finisher main control   board defective | 
        
            | SC733 | Stapler Exit Motor: B830The stapler exit motor is not operating.
 | • Motor harness loose, broken, defective •   Motor is blocked by an obstruction • Motor defective • Finisher main control   board defective | 
        
            | SC734 | Upper Tray Junction Gate Motor: 3K Finisher   B830The upper tray junction gate HP sensor did not detect the gate at the home   position within 200 ms after two attempts. -or- The HP sensor twice detected   the gate at the home position for more than 200 ms after it was supposed to   open.
 | • Junction gate did not arrive at the home   position within the specified time • Junction gate did not leave the home   position within the specified time | 
        
            | SC735 | Staple Junction Gate Motor Error: B830The staple tray junction gate HP sensor did not detect the gate at the home   position within 200 ms after two attempts. -or- The HP sensor twice detected   the gate at the home position for more than 200 ms after it was supposed to   open.
 | • Junction gate did not arrive at the home   position within the specified time • Junction gate did not leave the home   position within the specified time | 
        
            | SC736 | Pre-Stack Junction Gate Motor Error: 3K   Finisher B830The pre-stack junction gate HP sensor did not detect the gate at the home   position for within 200 ms after two attempts. -or- The HP sensor twice   detected the gate at the home position for more than 200 ms after it was   supposed to open.
 | • Junction gate did not arrive at the home   position within the specified time • Junction gate did not leave the home   position within the specified time | 
        
            | SC737 | Pre-Stack Transport Motor Error: B830The pre-stack transport motor is not operating.
 | • Motor harness loose, broken, defective •   Motor is blocked by an obstruction • Motor defective • Finisher main control   board defective | 
        
            | SC738 | Pre-Stack Junction Gate Release Motor Error:   B830The pre-stack junction gate release HP sensor did not detect the gate at the   home position within 200 ms after two attempts. -or- The HP sensor twice   detected the gate at the home position for more than 200 ms after it was   supposed to open.
 | • Junction gate did not arrive at the home   position within the specified time • Junction gate did not leave the home   position within the specified time |